CHINA FACTORY HPB SERIES SLIDING VANE PUMP POSITIVE DISPLACEMENT PUMP, SUITABLE FOR CONVEYING GASOLINE, DIESEL, KEROSENE AND OTHER LIGHTWEIGHT OILS

CHINA FACTORY HPB SERIES SLIDING VANE PUMP POSITIVE DISPLACEMENT PUMP, SUITABLE FOR CONVEYING GASOLINE, DIESEL, KEROSENE AND OTHER LIGHTWEIGHT OILS
Loading...
  • CHINA FACTORY HPB SERIES SLIDING VANE PUMP POSITIVE DISPLACEMENT PUMP, SUITABLE FOR CONVEYING GASOLINE, DIESEL, KEROSENE AND OTHER LIGHTWEIGHT OILS
Product name : CHINA FACTORY HPB SERIES SLIDING VANE PUMP POSITIVE DISPLACEMENT PUMP, SUITABLE FOR CONVEYING GASOLINE, DIESEL, KEROSENE AND OTHER LIGHTWEIGHT OILS
Product No. : 20225694840
←[Previous Product]              [Next Product]→
Details:
 Details
HPB sliding vane pump is a positive displacement pump, its operating temperature range is -40℃-80℃, it is suitable for conveying light oil products such as gasoline, diesel oil and kerosene. The main features of the sliding vane pump are stable performance, large flow, simple structure, convenient maintenance and movable work. It is widely used in gas stations, oil depots, docks, airports and other places. It is a good power equipment for supplying and unloading oil (no pumping).
working principle
HPB Sliding Vane Pump The sliding vane is installed in the slotted rotor, and the rotor is eccentrically installed in the pump body. When the rotor rotates, the sliding vane slides out from the rotor and slides against the inner surface of the pump. The cavity formed by the rotor, the sliding vane and the pump body changes periodically with the rotation of the rotor. The cavity increases. When it is large, it sucks in the medium, and when the cavity becomes small, it discharges the medium, and it starts over and over again to complete the medium conveying process.
Model meaning:
Note: 50HPB-20K (model description)
①.50---- means "caliber"
②.HPB--- means sliding vane pump
③. Indicates flow (m?/h)
④. Indicates "pump with relief valve"
Maintenance and use of HPB sliding vane pump:
1. For the normal operation of the oil pump, check whether the connection of each component is firm, whether the pipeline is unobstructed, and whether the electrical system and grounding wire are firm before starting the pump. Because the pump is mostly used in flammable and explosive places. For this, please find an electrician to operate it according to the procedures related to operation, protection and common sense of electrical appliances and circuit systems. Install AC contactor (0-10A) and motor protector (0-10A) at the front of the pump power supply section.
2. For a new pump or a pump that has not been used for a long time, an appropriate amount of oil should be injected into the pump to lubricate the parts in the pump before working.
3. In order to improve the self-priming ability of the pump, the sealing of each connection of the oil suction pipeline should be intact before use, and there should be no air leakage.
4. The length of the suction line of the pump should not exceed the performance parameters of the pump, and it should be 6-7 meters.
5. It is forbidden to install fuel guns, valves and other equipment at the outlet of the pump. To install Select pump body with relief valve.
6. After connecting the electrical circuit and oil pipeline, and making preparations before each work, the motor should be started instantly, and the direction of the arrow on the motor should be checked from the rear fan cover of the motor.
7. After the pump is started for 30 seconds, if the oil still cannot be delivered normally, the pump should be stopped to check the cause.
8. In order to prevent the oil pump from inhaling large particles, a filter is installed at the oil inlet. The filter will be blocked by small debris such as cotton, which will affect the oil absorption of the pump. Therefore, the filter should be checked and cleaned frequently. . If the filter is damaged, it should be replaced in time.
9. There is an oil drain hole at the lower part of the back cover of the pump. When oil overflows from the oil drain hole, it means that the shaft skeleton oil seal on the back cover has been aged and damaged, and should be replaced in time (if there is oil overflowing from the oil drain hole, do not block it. into the motor as liquid).
10. When the pump is used for a long time, the pump should be filled with oil and stored after being sealed.


Oil pump model Main performance indicators electric motor
Flow m3/h head m suction lift m Caliber m Voltage Power kw
HPB-19K 3.6 20 7 19 220V 0.75
25HPB-4.5K1 4.5 20 7 25 220V 1.1
32HPB-7.5K 7.5 20 7 32 220V 1.1
25HPB-10 10 20 7 25 380V 1.1
25HPB-10K 10 20 7 25 380V 1.1
38HPB-15 15 20 7 38 380V 1.1
38HPB-15K 15 20 7 38 380V 1.1
50HPB-20 20 20 7 50 380V 1.5
50HPB-20K 20 20 7 50 380V 1.5
80HPB-40 40 25 7 80 380V 4
GROUP OF COMPANY SEALOCEAN- we are leading manufacture for electric motor, Our main Motor products can be divided into 8 categories with 50 kinds of specifications as follow: 1) YB2 Series Explosion-proof Three-Phase Asynchronous Induction Motors for... [View More]
Service... [View More]
Name: Manager On Duty
Tel : 15985840856
Fax : +86059260180000
QQ: 2119098020
Skype: miss.rosly
Skype: [email protected]
Skype: edgeyou
E-mail: [email protected]
E-mail: [email protected]
E-mail: [email protected]
E-mail: [email protected]
Add: Hubin West Road, Xiamen City, China.
QQ: 2119098020
skype: miss.rosly
skype: info@sealocean-international.com
skype: edgeyou
email: sealocean@outlook.com
email: info@sealocean-international.com
email: sale@sealocean-international.com
email: tech@sealocean-international.com
facebook: https://www.facebook.com/profile.php?id=100016508982681
twitter: https://twitter.com/Sealcoean
youtube: https://www.youtube.com/channel/UCE7i8aEQ7Pw_x3rCo7O5obw
Linkedin: https://www.linkedin.com/in/эмма-сеалоцеан-82a29b141/
   Google |
Copyright © Group of company "SEALOCEAN" All Rights Reserved   sitemap  UA-101248356-1