China factory Sealcoean project (4)of middle and large size Dc, Ac,high voltage electric motor,Alternator


  These supplied alternators and motors have been used for marine engine., power plant, hydro power plants, such as HFO engines diesel engines made by Deutz, Sulzer and Japanese engine. Through years of efforts, we have also supplied to contractors and end users from outside China.
Now main series of our products:
 
Main Products
 
Medium and large capacity high voltage Synchronous alternator, the series are TF, TFW.
Medium and large capacity high voltage Synchronous motor, the series are T, TM, TL
Generator for hydro power plant, series are SF, SFW
Large and medium capacity Asynchronous motors for industrial plants as steel mill and electric control system.
 
TFW and TF Series Middle or Low Speed AC Synchronous Generator Technical Data and Quotation

TFW, TF Series Middle or Low Speed AC Synchronous Generator Technical Data and Quotation
 
Item
Model
Rated value
Power factor
(LAG)
Cos
Frequency
(Hz)
rated operating condition
weight
(T)
Unit Price
(USD)
power
(KW)
Voltage
(KV)
electric current
(A)
Rotational speed
(r/min)
Exciter voltage
(V)
Exciter current
(A)
1
TFW320-6/850
320
0.4
577
1000
0.8
50
29
153
 
  16,587.30
2
TFW550-6/990
550
0.4
992
1000
0.8
50
40
149
 
  21,825.40
3
TFW1700-6/1250
1700
0.4
3067
1000
0.8
50
119
187
 
  78,571.43
 
4
TFW250-8/850
250
0.4
451
750
0.8
50
80
46
 
  16,587.30
5
TFW800-8/1180
800
6.3
91.7
750
0.8
50
50
220
6.5
  43,126.98
6
TFW800-8/1180
800
10
55
75
0.8
50
52
228
6.5
  43,126.98
7
TFW1000-8/1180
1000
0.4
1804
750
0.8
50
56
233
7.2
  47,841.27
8
TFW1000-8/1180
1000
6.3
114.6
750
0.8
50
66
221
8.5
  56,396.83
9
TFW1000-8/1180
1000
10.5
68.7
750
0.8
50
60
199
8.53
  57,619.05
10
TFW1200-8/1180
1200
6.3
137.5
750
0.8
50
65
214
9.5
  63,031.75
11
TFW1200-8/1180
1200
10.5
67
750
0.8
 
 
 
10
  66,349.21
12
TFW1700-8/1250
1700
13.8
89
900
0.8
60
76
200
11.5
  76,301.59
13
TFW5500-8/2150
5500
11
361
750
0.8
50
96
302
 
 253,174.60
 
14
TFW500-10/1180
500
0.4
902
600
0.8
50
48
171
5
  33,174.60
15
TFW600-10/1180
600
0.4
1083
600
0.8
50
55
172
5.6
  36,666.67
16
TFW1000-10/1430
1000
6.3
114
600
0.8
50
57
286
9.25
  61,460.32
17
TFW2100-10/1430
2100
13.8
110
720
0.8
60
89
189
18.6
 124,841.27
18
TFW2000-10/1730
2000
10.5
137
600
0.8
50
 
 
22
 145,968.25
19
TF3600-10/2150
3600
10.5
247
600
0.8
50
 
 
30
 199,047.62
20
TFW4000-10/2150
4000
10.5
275
600
0.8
50
96
293
 
 230,476.19
21
TFW5500-10/2150
5500
13.8
288
720
0.8
60
103.5
292
 
 288,095.24
22
TFW10000-10/2820
10000
10.5
687
600
0.8
50
155
330
 
 366,666.67
 
23
TFW500-12/1180
500
0.4
902
500
0.8
50
54.4
182
5.6
  37,190.48
24
TFW1500-12/1250
1500
0.45
2410
600
0.8
60
284
44
12
  79,619.05
25
TFW1000-12/1430
1000
6.3
114.6
500
0.8
50
90
205
14
  92,888.89
26
TFW1000-12/1430
1000
10.5
68.7
500
0.8
50
90
205
14.3
  96,031.75
27
TFW1250-12/1430
1250
0.4
2255.3
500
0.8
50
102
203.2
14.8
  98,301.59
28
TFW1250-12/1430
1250
6.3
143.2
500
0.8
50
107
198
15.5
 103,015.87
29
TFW1250-12/1430
1250
11
82
500
0.8
50
110
195
16.5
 106,158.73
30
TFW1500-12/1430
1500
0.4
2706
500
0.8
50
67
239
16
 106,158.73
31
TFW1350-12/1730
1350
6.3
154.7
500
0.8
50
98
209
17
 112,793.65
32
TFW1350-12/1730
1350
10.5
92.8
500
0.8
50
98
209
17
 113,492.06
33
TFW1600-12/1730
1600
0.4
2886.8
500
0.8
50
115
229
17.8
 118,730.16
TFW, TF series ac synchronous generator technology data
 
Item
Model
Rated value
Power factor
(LAG)
Cos
Frequency
(Hz)
rated operating condition
Weight
(T)
Unit Price
(USD)
Power
(KW)
Voltage
(KV)
Electric current
(A)
Rotational speed
(r/min)
Exciter voltage
(V)
Exciter current
(A)
34
TFW1600-12/1730
1600
6.3
171.8
500
0.8
50
121
191
17.8
 118,730.16
35
TFW1600-12/1730
1600
10.5
110
500
0.8
50
121
191
18.8
 124,841.27
36
TFW2000-12/1730
2000
0.4
3608.4
500
0.8
50
100.4
204
19
 126,587.30
37
TFW2000-12/1730
2000
10.5
137.5
500
0.8
50
148.4
214.3
20
 132,698.41
38
TFW2500-12/1730
2500
10.5
171.83
500
0.8
50
146
235
21.8
 144,746.03
39
TFW3000-12/2150
3000
10.5
206.3
500
0.8
50
96
273
28
 185,777.78
40
TFW3150-12/2150
3150
6.3
361
500
0.8
50
137.4
259.2
28
 185,777.78
41
TFW3150-12/2150
3150
10.5
217
500
0.8
50
151.5
259.1
29.5
 200,793.65
42
TFW5000-12/2150
5000
6.3
573
500
0.8
50
167
254
38
 253,174.60
43
TFW5000-12/2150
5000
11
328
500
0.8
50
135
278
40
 265,396.83
45
TFW8000-12/2600
8000
11
525
500
0.8
50
 
 
44
 323,015.87
46
TFW8000-12/2820
8000
13.8
418
600
0.8
60
117
415
 
 366,666.67
 
47
TFW400-14/1180
400
400
 
514
0.8
60
 
 
5.6
  37,190.48
48
TFW400-14/1180
400
440
 
428
0.8
50
 
 
5.6
  37,190.48
49
TFW1000-14/1730
1000
0.4
1804
428.6
0.8
50
100
174
12.1
  80,317.46
50
TFW1000-14/1730
1000
6.3
114.6
428.6
0.8
50
80
232
12.8
  84,857.14
51
TFW1000-14/1730
1000
10.5
68.7
428.6
0.8
50
92.5
202.6
13.5
  89,571.43
52
TFW2000-14/2150
2000
10.5
137.5
428
0.8
50
120
284
22
 156,444.44
53
TFW2000-14/2150
2000
0.4
3610
428
0.8
50
95
280
21
 139,333.33
54
TFW6500-14/2600
6500
11
426.5
428.6
0.8
50
 
 
 
 314,285.71
55
TFW8000-14/2820
8000
13.8
418
514
0.8
60
148
288
 
 366,666.67
56
TFW10000-14/2860
10000
11
656
428.6
0.8
50
 
 
53
 385,873.02
 
57
TFW550-24/2150
550
0.4
992
250
0.8
50
64
166
 
 
 
58
TFW1250-28/2600
1250
6.3
143.2
214
0.8
50
92
188
 
 
 
59
TFW10000-36/4250
10000
11
656
166.6
0.8
50
 
 
98
 770,000.00
 
60
TFW1500-40/3250
1500
0.415
 
150
0.8
50
145
202
34
 237,460.32
61
TFW2000-40/3250
2000
0.415
 
150
0.8
50
148
215
36
 258,412.70
62
TFW5000-40/4250
5000
11
328
150
0.8
50
 
 
70
 550,000.00
 
63
TFW1500-48/3250
1500
0.415
 
125
0.8
50
148
207
38
 265,396.83
64
TFW2000-48/3250
2000
0.415
 
125
0.8
50
148
225
40
 314,285.71
Note:
Adove are our low and middle speed alternator for hfo diesel generator, hydro power or wind power plant, we also design/manufacture to users' specific design or requirements. Above price list/quotation is only for reference.
Quotation code: 631020120306

Quotation on alternator
 Unit: USD/ set
Model Rated power Rated current Rated voltage Frequency Rotational speed Power factor Unit Price
TFW2500-8/1430 2500KW 164A 11KV 50Hz 750rpm 0.8 130,833.33
Remarks
1.Quotation is based upon FOB China ports, in US dollars.
2.Payment: 30% by T/T, balance be paid by T/T within 10 days after notice by email or fax stating alternator are ready for delivery at factory and buyer can inspect in factory if required by buyer.
3. delivery time: 6 months after advance payment
4. our producer has been supplying its alternator for MAN, Wartsila hfo engines, produced by their related licensees or jonit ventures.
5. quotation code: Denis McGrath630520111125

5 MW TFW1500-40/3250 Quotation on alternator
Quotation on alternator
 Unit: USD/ set
Model Rated power Rated current Rated voltage Frequency Rotational speed Power factor Exciter current Excitation voltage efficiency weight Unit Price
TFW5000-12/2150 5000KW 328A 11KV 50Hz 500rpm 0.8 278A 135V 96.50% 40T 268,296.53
Remarks
1.Quotation is based upon FOB China ports, in US dollars.
2.Payment: 30% by T/T, balance be paid by T/T within 10 days after notice by email or fax stating alternator are ready for delivery at factory and buyer can inspect in factory if required by buyer.
3. delivery time: 6 months after advance payment
4. our producer has been supplying its alternator for MAN, Wartsila hfo engines, produced by their related licensees or jonit ventures.
5. quotation code: Ümit Baki640520111116

Quotation on alternator   Quotation on alternator TFW1500-40/3250 1500KW 415V
Unit: USD/ set
Model Power (KW) Voltage (V) Electric current (A) Frequency (Hz) Rotational speed (rpm) Weight (t) Long (mm) Width (mm) Unit Price
High (mm)
TFW1500-40/3250 1500KW 415V 2608A 50Hz 150rpm 33t 3100mm 2450mm 4000mm 153,462.69
TFW1500-48/3250 1500KW 415V 2608A 50Hz 125rpm 38t 3200mm 3200mm 4000mm 196,179.14
Remarks
1.Quotation is based upon FOB China ports, in US dollars.
2.Payment: 30% by T/T, balance be paid by T/T within 10 days after notice by email or fax stating trucks are ready for delivery at factory and buyer can inspect in factory if required by buyer.
3.Packing: nuke packed.
4.Sea mode of transport: Bulk Carrier
5.Delivery: TFW1500-40/3250: Three month, TFW1500-48/3250: 5-6 months after contracts effective.
6.Price valid: 30 days from Sep.17th, 2010.
7.quotation code: 617136720100917

Quotation on alternator   Quotation on alternator of model TFW1500-40/3250
Unit: USD/ set
Model Rated Power (KW) Voltage (V) Electric current (A) Frequency (Hz) Rotational speed (rpm) Weight (t)
TFW1500-40/3250 1500KW 415V 2608A 50Hz 150rpm 33t
Remarks
1.Quotation is based upon FOB China ports, in US dollars.
2.Payment: 30% by T/T, balance be paid by T/T within 10 days after notice by email or fax stating trucks are ready for delivery at factory and buyer can inspect in factory if required by buyer.
3.Packing: suitable for sea transportation.
4.Sea mode of transport: Bulk Carrier
5.Delivery: Three month, day after contracts effective.
6.Price validility: 30 days from Sep.16th, 2010.
7.quotation code: 617136720100916

 
GROUP OF COMPANY SEALOCEAN- we are leading manufacture for electric motor, Our main Motor products can be divided into 8 categories with 50 kinds of specifications as follow: 1) YB2 Series Explosion-proof Three-Phase Asynchronous Induction Motors for... [View More]
Service... [View More]
Name: Manager On Duty
Tel : 15985840856
Fax : +86059260180000
QQ: 2119098020
Skype: miss.rosly
Skype: [email protected]
Skype: edgeyou
E-mail: [email protected]
E-mail: [email protected]
E-mail: [email protected]
E-mail: [email protected]
Add: Hubin West Road, Xiamen City, China.
QQ: 2119098020
skype: miss.rosly
skype: info@sealocean-international.com
skype: edgeyou
email: sealocean@outlook.com
email: info@sealocean-international.com
email: sale@sealocean-international.com
email: tech@sealocean-international.com
facebook: https://www.facebook.com/profile.php?id=100016508982681
twitter: https://twitter.com/Sealcoean
youtube: https://www.youtube.com/channel/UCE7i8aEQ7Pw_x3rCo7O5obw
Linkedin: https://www.linkedin.com/in/эмма-сеалоцеан-82a29b141/
   Google |
Copyright © Group of company "SEALOCEAN" All Rights Reserved   sitemap  UA-101248356-1